Gold Member Since 2008
Audited Supplier
Dongguan Golden Refrigeration Equipment Co., Ltd.

Water Cooled Chiller, Water Chiller, Cooled Water Chiller manufacturer / supplier in China, offering Air Conditioning System Water Chiller, High Efficiency Fcu Horizontal Expose Fan Coil Unit, 9.2-142.2kw Air Cooled Industrial Packaged Water Chiller and so on.

(/ )

Supplier Homepage Product Water cooled chiller Air Conditioning System Water Chiller

Air Conditioning System Water Chiller

FOB Price: US $5,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $5,000/ Piece
Get Latest Price
Production Capacity: 500 Units/Month
Transport Package: Wooden Case
Payment Terms: L/C, T/T, D/P, Paypal, Money Gram, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HLWW-535S
  • Air Tube Material: Plastics
  • Operating Voltage: 380/400 VAC
  • Application Fields: Mechanical Engineering
  • Lifetime: 10~15 years
  • Condition: New
  • Condenser: Shell and Tube Type
  • Chilled Water Range: 5~20deg
  • Compressor: Screw Type
  • Cooling Method: Indirect Cooling
  • Chilled Water Flow: 91.9-262.5m3/H
  • Specification: CE
  • HS Code: 8418692090
  • Type: Chiller
  • Corrosion Durability: General
  • Noise Level: Ordinary
  • Mounting: Floor Standing
  • Certification: CE
  • Cooling Capacity: 534kw-1526kw
  • Power Supply: 3pH-380V-50Hz
  • Cooling Water Range: 15~40deg
  • Usage: for Air Conditioner
  • Refrigerant: R22, R407c, R410A etc
  • Trademark: Golden
  • Origin: Dongguan, China.
Product Description
Air conditioning system water chiller



Applications:
Electroplating, plastic products, hardware, chemical industry, electronics, food preservation,
Laser carving, vacuum coating, ultrasonic cleaning etc industries.

Chiller that uses high effective a easy cleaning stainless steel heat exchanger, exerts its
Unique advantage against erosion and filth in electroplating, PCB, oxidization, chemical
Industry, etc weak acid and alkaline conditions.

Spare parts introduction:
Packaged -type chiller including water pump and water tank. Client can choose with or without water pump and water tank.
Compressor: Hitachi, Daikin, Danfoss, Copeland, client can choose the compressor
Water cooled type: Condenser and evaporator use Shell-and-tube.
Air cooled type: Shell-and-tube condenser, finned type evaporator

Safety production Device:
Besides the features of tank water-cooled machine set, air blast cooling chiller does not need extra cooling water tower and is easy to install and operate so that it is suitable for small production equipments.
Phase reversion protection, Phase lack protection, overload current protection, discharge air temp. Protection, low &high pressure protection.

Function:
Refrigerant: R22/R407c/R134, client can choose the refrigerant/gas.
Cooling only unit/cooling-heating unit,
1. Adopt the advanced scroll compressor, resistance low temp and high efficiency
2. Electrical configuration adopt high quality product of the world to ensure that the unit stable quality and reliable operation.
3. Equipped with high-performance low temp freezing pump and stainless steel water tank
4. Adopt the glycol antifreeze as the cooling agent, freezing water temp can be controlled at -25 degrees Celsius.
5. Customer may request calcium chloride as an antifreeze.



   Model     HLWW~535S580S600S700S770S820S925S1130S1335S1525S
535SR580SR600SR700SR770SR820SR925SR1130SR1335SR1525SR
 
Rated Cooling Capacity  
×1000Kcal/h459.3497.5516.6601.6660.8705.5795.2974.61148.41312.3
KW534579601700769821925113413361526
USRT151.9164.5170.8198.9218.5233.3263.0322.3379.8433.9
  lnput powerKW111.7120.3124.1143.0158.7168.4189.4231.1270.8306.4
  Comp. Current (A)197.7 212.8219.6 253.0280.7298.1 335.2409.0 479.2542.1
  Refrigerant R22
   Power Supply 3φ-380V-50HZ
  Safety ProtectionPhase reversion protection, Phase lack protection, Overload current protection, Discharge air temp. protection, Low & High pressure protection, Low temp. protection, Water flow protection.
  Number of Refrigeration Circuit1
  Capacity Control (%)0, 50, 75, 100
   Refrigerant Charge (kg)97105109127141150168207243277
  CondenserShell and Tube Type
  Water Side Max Pressure (MPa)1
  Dia. of Pipe to Condenser (inch)5"5"5"5"5"5"6"6"8"8"
  Cooling Water Flow  (m3/h)111.1120.2124.7144.9159.4170.1191.6234.7276.3315.2
  Condenser Water Pressure drop (kPa) 51515865676871748489
  EvaporatorShell and Tube Type
  Water Side Max Pressure (MPa)1
  Dia.of Pipe to Evaporator (inch)5"5"5"5"5"5"5"8"8"8"
   Chilled Water Flow (m3/h)91.999.5103.3120.3132.2141.1159.0194.9229.7262.5
  Evaporator Water Pressure drop (kPa)47637940586972747679
  Running Noise dB(A)86.386.686.987.187.387.688.490.390.891.2
  Total weight (kg)2270246025402680290030603310374039804300
   Running Weight(kg)2520272029203060338036003830426045204840

Send your message to this supplier
Avatar
Ms. Aysha Wan
Superintendent
*From:
To: Ms. Aysha Wan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now