Gold Member Since 2008
Audited Supplier
Dongguan Golden Refrigeration Equipment Co., Ltd.

Air Cooled Chiller, Air Chiller, Air Source Chiller manufacturer / supplier in China, offering 358kw-632kw Double Compressor High Cop Screw Air Cooling Chiller, Ceiling Concealed Duct Fan Coil Unit, 503kw Air Cooled Screw Chiller with Punp Control System and so on.

(/ )

Supplier Homepage Product Air cooled chiller 358kw-632kw Double Compressor High Cop Screw Air Cooling Chiller

358kw-632kw Double Compressor High Cop Screw Air Cooling Chiller

FOB Price: US $40,000 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $40,000/ Piece
Get Latest Price
Production Capacity: 100 Units/Month
Transport Package: Wooden Case
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: HLWA~520DM
  • Certification: CE
  • Cooling Capacity: 358kw-632kw
  • Usage: for Refrigerate, for Air Conditioner, for Manufa
  • Compressor: Hanbell
  • Trademark: Golden
  • Origin: Dongguan, Guangdong
  • Type: Air-Cooled
  • Condition: New
  • Chilled Water Flow: 1026L/M
  • Cooling Method: Direct Cooling
  • Refrigerant: R22,R407c.R134A,R410A
  • Specification: CE
  • HS Code: 8418612090
Product Description
Applications:

1. Use for cooling equipment/machine (Electroplating, plastic products, hardware, chemical industry, electronics, food preservation, laser carving, vacuum coating, ultrasonic cleaning etc industries. )

2. Working on central air conditioner system.

Compressor: Hanbell, Bitzer, Refcomp, client can choose the compressor

Safety production Device:

Besides the features of tank water-cooled machine set, air blast cooling chiller does not need extra cooling water tower and is easy to install and operate so that it is suitable for small production equipments.
Phase reversion protection, Phase lack protection, overload current protection, discharge air temp. Protection, low &high pressure protection.

Function:

Refrigerant: R22/R407c/R134, client can choose the refrigerant/gas.
1. Adopt the advanced scroll compressor, resistance low temp and high efficiency

2. Electrical configuration adopt high quality product of the world to ensure that the unit stable quality and reliable operation.

3. Equipped with high-performance low temp freezing pump and stainless steel water tank

4. Adopt the glycol antifreeze as the cooling agent, freezing water temp can be controlled at -25 degrees Celsius.

5. Customer may request calcium chloride as an antifreeze.
                                                                                                                                                                                                                                  Air  cooled  screw  Chiller  (with  Heat  Recovery)
          Model          HLWA~ 380DM 420DM 480DM 520DM 560DM 620DM 680DM
380DHM 420DHM 480DHM 520DHM 560DHM 620DHM 680DHM

Rated  Cooling  Capacity
X  1000Kcal/h 307.8 336.2 399.0 421.3 460.9 503.9 543.4
KW 358 391 464 490 536 586 632
  ×   Comp.   lnput  Power× Qty  (KW) 58.2× 2 63.8× 2 70.5× 2 74.1× 2 82.4× 2 90.2× 2 98.9× 2
  Refrigerant  R407C
    Power  Supply  380V/  3ph/  50Hz
  Safety  Protection ,   ,   ,   ,   ,   ,  
Phase  reversion  protection,   Phase  lack  protection,   Overload  current  protection,
Discharge  air  temp.     protection,   Low  &   High  pressure  protection,   Low  temp.     protection,   Water  flow  protection.
    Number  of  Refrigeration  Circuit 2
  Capacity  Control  (%) 0,   25,   37.5,   50,   62.5,   75,   87.5,   100
    Refrigerant  Charge  (Kg) 104 112 136 142 156 168 186
      Condenser     Ripple  Aluminum  Fins  Around  Copper  Pipe

Evaporator
    Dia. of  Pipe  (inch) 5" 5" 3" × 2 3" × 2 4" × 2 4" × 2 4" × 2
   
Water  Side  Max  Pressure    (MPa)
1

Chilled    Water  Flow(m3/h)
61.6 67.2 79.8 84.3 92.2 100.8 108.7
  Water  Pressure  drop  (kPa)  42 54 44 52 54 55 65

Axial  Fan
× 1000m3/h 
Air  Flow× 1000m3/h
172.8 172.8 230.4 230.4 230.4 321.6 321.6
×   Power× Qty  (KW) 1.2× 12 1.2× 12 1.2× 16 1.2× 16 1.2× 16 2.0× 16 2.0× 16
    Running  Noise  dB(A) 72 72 72 72 75 75 75
    Total  Weight  (Kg) 4430 4550 5340 5420 5500 5860 6320
    Running  Weight(Kg) 4750 4970 5800 5950 6040 6480 6900
                   
    Heat  Recovery 
    Refrigerant  Charge  (Kg) 110 118 142 148 160 174 192
 
Heat  Reclaimed  Volume  (kw)
X  1000Kcal/h 92.3 100.9 119.7 126.4 138.3 151.2 163.0
KW 107 117 139 147 161 176 190

  Heat  Recovery
  Dia. of  Pipe  (inch) 2-1/2" 2-1/2" 2" × 2 2" × 2 2" × 2 2" × 2 2" × 2
 
Water  Side  Max  Pressure    (MPa)
 
Reclaimed    Water  Flow  (m3/h)
18.5 20.2 23.9 25.3 27.7 30.2 32.6
  Water  Pressure  drop  (kPa)  26 26 27 27 30 30 34
    Total  Weight  (Kg) 4790 4910 5920 6040 6260 6480 6980
    Running  Weight(Kg) 5280 5440 6500 6650 6760 7240 7720
Send your message to this supplier
Avatar
Ms. Aysha Wan
Superintendent
*From:
To: Ms. Aysha Wan
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now